5KW Pure Sine Wave Solar Inverter HFP Series
Home » Products » Accessories » 5KW Pure Sine Wave Solar Inverter HFP Series

5KW Pure Sine Wave Solar Inverter HFP Series

  • Full digital double closed-loop control, combined with advanced SPWM technology to output pure sine wave;
  • 2 output modes: mains bypass and inverter output for uninterrupted power supply;
  • 4 charging modes: Solar Only, Mains Priority, Solar Priority, and Solar&Mains Charging;
  • Advanced MPPT technology ensures 99.9% efficiency;
  • ON/OFF rocker switch for AC output control;
  • Power saving mode available to reduce no-load loss;
  • Intelligent adjustable speed fan for efficient heat dissipation and extended system life;
  • Full protection, including overload and short circuit protection, under-voltage and over-voltage protection, and reverse polarity protection;
  • LCD screen and LED indicator design for real-time display of system data and operating status;
  • Support 6 units parallel connection.
Availability:

Models

HFP4850S80-145

AC mode

Rated input voltage

220/230Vac

Input voltage range

(170Vac~280Vac) ±2%;(90Vac-280Vac)±2%

Frequency

50Hz/ 60Hz (Auto detection)

Number of parallel / split phases

1-6

Frequency Range

47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);

Overload/short circuit protection

Circuit breaker

Efficiency

>95%

Conversion time (bypass and inverter)

10ms (typical)

AC reverse protection

Available

Maximum bypass overload current

40A

Inverter mode

Output voltage waveform

Pure sine wave

Rated output power (VA)

5000

Rated output power (W)

5000

Power factor

1

Rated output voltage (Vac)

230Vac

Output voltage error

±5%

Output frequency range (Hz)

50Hz ± 0.3Hz/60Hz ± 0.3Hz

Maximum Efficiency

>92%

Overload protection

(102% < load <125%) ±10%: report error and turn off the output after 5 minutes;
(125% < load < 150%) ±10%: report error and turnoff the output after 10 seconds;
Load >150% ±10%: report error and turn off the output after 5 seconds;

Peak power

10000VA

Loaded motor capability

3HP

Output short circuit protection

Circuit breaker

Bypass breaker specifications

40A

Rated battery input voltage

48V (Minimum starting voltage 44V)

Battery voltage range

Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery... settable on LCD screen

Power saving mode

Load ≤50W

AC charging

Maximum charge current

60A

Charge current error

± 3Adc

Charge voltage range

40 –58Vdc

Short circuit protection

Circuit breaker and blown fuse

Circuit breaker specifications

40A

Overcharge protection

Alarm and turn off charging after 1 minute

PV charging

Maximum PV open circuit voltage

145Vdc

PV operating voltage range

60-145Vdc

MPPT voltage range

60-115Vdc

Battery voltage range

40-60Vdc

Maximum PV input power

4400W

Maximum PV input current

50A

Maximum charger power

4200W

PV charging current range (can be set)

0-80A

Charging short circuit protection

Blown fuse

Wiring protection

Reverse polarity protection

Certified specifications

Certification

CE(IEC 62109-1)

EMC certification level

EN61000, C2

Operating temperature range

-15°C to 55°C

Storage temperature range

-25°C to 60°C

Humidity range

5% to 95% (Conformal coating protection)

Noise

≤60dB

Heat dissipation

Forced air cooling, variable speed of fan

Communication interface

USB/RS485(WiFi/GPRS)/Dry node control

Size (L*W*D)

426*322*124 mm (16.8*12.7*4.9 in)

Weight 

10.8 kg (24 lbs)


Product Inquiry

CONTACT US

 +86-755-28906569
1010 Longnian Bld, 29 Longcheng Ave, Nanlian Area, Longgang St, Longgang Dist, Shenzhen, China 518116