Choosing sodium-ion batteries for energy storage involves more than comparing capacity. 

Rack-mounted modules offer flexible system configuration, while outdoor cabinets integrate multiple components into one enclosure. Each has different requirements for equipment matching, installation, and future expansion. Choosing the wrong setup can increase integration work and installation costs. 

This guide compares both options and explains how to select the right Polinovel solution for your project.

Rack Modules and Outdoor Cabinets: Two Different System Architectures

Polinovel's product configurations provide a practical way to understand how different sodium-ion energy storage systems are built. The rack-mounted range uses individual 51.3V battery modules, while the CBS54 and CBS116 outdoor cabinets use 45.6V battery modules connected in series to form higher-voltage systems.

How Rack-Mounted Sodium-Ion Battery Systems Are Configured

Polinovel's rack-mounted sodium-ion battery range includes three 51.3V capacity options. Each battery works as an individual energy storage unit and can be connected with compatible modules to build a larger battery bank.

Model

Nominal Energy

51.3V 50Ah

2.565kWh

51.3V 100Ah

5.13kWh

51.3V 170Ah

8.72kWh

All three models support up to 20 units in parallel. This allows the nominal storage capacity to increase as project requirements grow, subject to inverter compatibility and system configuration.

Each battery also includes several functions for system operation:

  • Built-in BMS: Monitors battery voltage, temperature, and other operating conditions while providing protection against abnormal conditions.

  • CAN / RS485 Communication: Enables data exchange with compatible inverters and monitoring equipment.

  • Natural Cooling: Supports indoor installation without a dedicated liquid-cooling system.

However, connecting battery modules is only one part of system configuration. A complete installation also requires a compatible energy storage inverter, electrical protection devices, and properly rated connections. For example, the inverter must match the battery's voltage range and charging parameters. The BMS communication protocol must also be compatible with the selected equipment.

How Integrated Outdoor Sodium-Ion Cabinets Are Designed

For integrated higher-voltage storage configurations, Polinovel offers the CBS54 and CBS116 outdoor sodium-ion energy storage cabinets. Unlike the 51.3V rack-mounted batteries, these systems use 45.6V 170Ah internal battery modules, each providing 7.75kWh of nominal energy.

The modules are connected in series to form higher-voltage battery systems.

Model

Battery Modules in Series

System Voltage

Nominal Energy

CBS54

7

319.2V

54.26kWh

CBS116

15

684V

116.2kWh

Beyond the battery assembly, the cabinet integrates the main components needed for energy storage and power conversion:

  • Battery Management: BMS and high-voltage unit for battery monitoring and system control.

  • Power Conversion: Integrated hybrid inverter for DC-to-AC power conversion.

  • Thermal Management: Intelligent air cooling to regulate internal operating temperatures.

  • Fire Protection: Built-in aerosol fire suppression.

The enclosure is designed for outdoor installation, with IP54 protection and C4-M corrosion protection. CAN/RS485 communication and local and remote monitoring are also supported.

These cabinets support both grid-connected and off-grid operation. They can be configured for applications such as peak shaving and solar self-consumption.

Although major components are integrated before delivery, site preparation, electrical connections, and system commissioning are still required. The final setup must match the site's electrical conditions and intended operating strategy.

Rack Modules vs. Outdoor Cabinets: Key Differences

The differences between rack-mounted batteries and outdoor cabinets extend beyond their physical design. Their system integration, installation requirements, and expansion methods can affect the overall project configuration.

Comparison Factor

Rack-Mounted Battery Systems

Outdoor Cabinet Systems

System Architecture

Individual 51.3V battery modules.

45.6V modules connected in series to form a high-voltage system.

Nominal Energy

2.565–8.72 kWh per module.

54.26 kWh (CBS54) / 116.2 kWh (CBS116).

System Integration

Requires an external compatible inverter and supporting equipment.

Integrates BMS, high-voltage unit, and hybrid inverter.

Voltage Configuration

51.3V per module; system voltage depends on connection configuration.

319.2V (CBS54) / 684V (CBS116).

Thermal Management

Natural cooling.

Intelligent air cooling.

Enclosure Protection

IP20, designed for indoor installation.

IP54 with C4-M corrosion protection, designed for outdoor installation.

Capacity Expansion

Up to 20 units in parallel, subject to system compatibility.

Expansion depends on cabinet configuration and supported system connections.

What Do These Differences Mean for Your Project?

  • Rack-mounted systems provide more flexibility in battery configuration and external equipment selection. However, system integrators need to pay closer attention to inverter compatibility, electrical connections, and installation conditions.

  • Outdoor cabinets bring more components together in one enclosure. This can simplify equipment coordination and on-site assembly, although the cabinet's rated power, installation conditions, and system interfaces still need to match the project requirements.

Neither configuration is universally better. The choice depends on the project's electrical design, installation environment, and future capacity requirements.

Which Configuration Is Better for Different Energy Storage Applications?

The choice between rack-mounted batteries and outdoor cabinets becomes clearer when looking at how a site uses electricity. Some projects need flexible battery capacity for indoor installation, while others require a higher-capacity storage system designed for outdoor deployment.

When Are Rack-Mounted Sodium-Ion Batteries a Better Fit?

Rack-mounted batteries are worth considering for projects that need modular storage capacity and have suitable indoor installation space. Their individual modules allow the battery bank to be configured around the required energy demand.

Common applications include:

  • Residential Solar Energy Storage: Homeowners can store excess solar generation during the day and use it later when solar output decreases. The battery configuration should account for household consumption, backup requirements, and inverter compatibility.

  • Telecom Backup Power: Communication sites need backup systems that can keep essential equipment running during grid interruptions. Rack-mounted batteries can be considered when their voltage range, charging parameters, and communication interfaces match the site's DC power requirements.

  • Modular Backup Systems: Facilities planning to expand their backup capacity over time may benefit from individual battery modules. Additional units can be added when the BMS, inverter, and electrical connections support the expanded configuration.

Polinovel's 51.3V sodium-ion battery range, available in 50Ah, 100Ah, and 170Ah options, provides different starting capacities for these applications.

When Are Outdoor Sodium-Ion Cabinets a Better Fit?

Outdoor cabinets are worth considering when a project requires a consolidated storage system with integrated power conversion and supporting equipment. They can be particularly useful at commercial and industrial sites where indoor installation space is limited.

Their potential applications include:

  • Commercial and Industrial Energy Storage: Factories and commercial facilities can use battery storage to manage electricity demand and improve energy utilization. System sizing should consider the facility's load profile, required discharge power, and daily operating schedule.

  • Solar Self-Consumption: Sites with rooftop or ground-mounted solar installations can store surplus generation for later use. Battery capacity, inverter power, and charging schedules should be coordinated with solar production and electricity consumption.

  • Peak Shaving: Facilities with short periods of high electricity demand can discharge stored energy to reduce grid power consumption during peak periods. The required discharge power and duration are particularly important when sizing the system.

For these applications, Polinovel offers two integrated outdoor sodium-ion cabinet options: the CBS54 with 54.26kWh and the CBS116 with 116.2kWh of nominal energy. Both provide a cabinet-based configuration for commercial and industrial storage projects.

The application examples above provide a starting point for selecting a system architecture. Actual configurations still need to be checked against energy consumption, load characteristics, and required operating duration.

What Should You Consider When Choosing Sodium-Ion Batteries for Energy Storage?

Choosing sodium-ion batteries for energy storage requires more than checking nominal capacity. The battery configuration must also match the site's load profile, inverter requirements, installation environment, and future expansion plans.

For Polinovel's rack-mounted batteries and outdoor cabinets, the selection process involves several key considerations.

1. Define Your Energy Requirements

Start by understanding how much energy the system needs to store and deliver. Daily electricity consumption alone may not be enough to determine the required battery capacity.

Consider the following:

  • Daily Energy Consumption: How much electricity does the site use?

  • Backup Duration: How long must the battery supply power?

  • Critical Loads: Which equipment needs continuous power?

  • Usable Capacity: How much energy can the system actually deliver within its operating limits?

Nominal capacity is not the same as usable energy. Depth of discharge (DOD), system efficiency, and operating reserves all affect the available energy.

Once these requirements are clear, compare them with the available battery configurations. Polinovel's rack-mounted range offers 50Ah, 100Ah, and 170Ah modules, while the CBS54 and CBS116 cabinets provide 54.26kWh and 116.2kWh of nominal energy, respectively.

2. Match Battery Capacity with Power Demand

Energy capacity and power output serve different purposes. Capacity, measured in kWh, determines how much energy the battery stores. Power, measured in kW, determines how much electricity the system can deliver at a given time.

Both must meet the site's operating requirements.

For example, a facility may have enough stored energy for several hours of operation but still require a higher inverter output to support simultaneous loads or motor starting currents.

Before selecting a system, check:

  • Continuous load power and peak demand.

  • Starting current of motors and other high-power equipment.

  • Maximum battery discharge current.

  • Required inverter output power.

For outdoor cabinets, pay particular attention to the integrated hybrid inverter's rated AC output. A cabinet's nominal energy capacity alone does not indicate whether its output can support the site's loads.

3. Verify Inverter and Electrical Compatibility

The battery configuration must work within the selected inverter's electrical and communication limits.

For rack-mounted systems, each battery module has a nominal voltage of 51.3V and requires an external compatible inverter. Check that the inverter's DC input voltage range matches the configured battery bank. Charging and discharging current limits must also remain within the battery's specifications.

For CBS54 and CBS116 outdoor cabinets, the battery modules are connected in series to form nominal system voltages of 319.2V and 684V, respectively. Both configurations integrate a hybrid inverter, reducing the need for separate inverter selection.

However, integration does not remove the need for electrical checks. Confirm the cabinet's rated AC output power, output voltage, frequency, phase configuration, and grid-connected or off-grid operating requirements.

CAN or RS485 communication, electrical protection, and applicable grid connection requirements should also be verified before installation.

4. Evaluate Installation Conditions and Expansion Plans

The installation environment influences enclosure selection, thermal management, and long-term maintenance.

Rack-mounted batteries use natural cooling and are intended for indoor installation. They offer a modular configuration, with up to 20 compatible units connected in parallel. This provides flexibility when planning additional storage capacity, subject to BMS, inverter, and connection requirements.

Outdoor cabinets take a more integrated approach. Polinovel's CBS54 and CBS116 feature IP54 protection, C4-M corrosion protection, and intelligent air cooling. These features support outdoor deployment, although site conditions, installation clearance, and maintenance access still need to be assessed.

Expansion also requires different planning. Rack-mounted systems can add compatible modules within the supported parallel limit, while cabinet expansion depends on the available cabinet configuration and supported system connections.

Operating conditions can influence battery performance and service life, although their effects vary by battery chemistry. In a study of grid-connected lithium-ion energy storage, researchers at the National Renewable Energy Laboratory (NREL) examined how temperature, depth of discharge (DOD), and charge/discharge rates affect battery aging. Although the study focuses on lithium-ion cells, it provides useful background for understanding battery life evaluation. Therefore, cycle-life figures should always be reviewed alongside their test conditions rather than compared as standalone numbers.

Finally, review product certifications, warranty terms, and technical support arrangements before making a purchasing decision.

Choosing sodium ion batteries for energy storage is ultimately a system-level decision. The right configuration needs to work with the site's electrical infrastructure and actual operating requirements, not just meet a target battery capacity.

Planning an energy storage project? Share your application and electrical requirements with Polinovel to discuss a suitable sodium-ion battery configuration.

Discuss Your Project With Us

⚠ For B2B projects and inquiries. Commercial, industrial, OEM, and project-based requirements are welcome.
RV

CONTACT US

 +86-755-28906569
Shenzhen Headquarter: 
Building 3, Vanke Timemark, 85 Longcheng Ave, Longgang Dist, Shenzhen, China

QUICK LINKS

PRODUCT SHOWCASE

INDUSTRY APPLICATIONS

Copyright © 2006-2026 Polinovel All Rights Reserved